Fujica stx-1, Fomapan 200 and Caffenol C-M

I first tried caffenol a couple of months ago and had limited success, mostly because the agfa daylight tank I was using didn’t load correctly so I ended up with a section of film which didn’t get developed. My next attempt was a bit more successful, because at least all the images got developed, but I still had problems, I think because the images were under developed. So, determined to have another go, I loaded a fujica stx-1 which I recently acquired with a roll of Fomapan 200 and had a walk around Stevenage taking some trial shots.

For this set of images, I used the same Caffenol C-M recipe which I used for the last two experiments, but this time I tried a longer development time of 15 minutes. On this occasion, once the develpment was complete and I removed the film from the tank,  the images on the film looked pretty good, but when scanned on our HP Photosmart C8100 they once again came out completely awful, with very low contrast and were almost completely un-recoverable in Lightroom. I think that our scanner is working out the ‘exposure’ by averaging across the whole film strip so if one frame is incorrectly exposed the whole strip suffers.

So I tried duplicating the film using a slide duplicator and had much more success, although there are still issues which need to be sorted out. The biggest problem with the duplication method is that my slide duplicator doesn’t have a film strip holder so I have to position the film in the slide carrier and hold it at best I can whilst I take the picture. Because I want to maximize the depth of field I normally use about f/8 which results in quite long exposure times. In itself that doesn’t matter if the film is being held securely in a film strip holder, but it is a bit hairy when I’m holding it with my fingers!

Once I had the pictures duplicated and on a memory card, I imported them into Lightroom. I then set them to black & white to remove the slightly sepia tone in the duplicated image, and reversed the image using the Lightroom tone curve tool. Each image had to be individually cropped from the duplicated picture which was too large, and had a bit of exposure correction (about 1/2 stop). As well as the gallery above you can view the full sized pictures by following this link and navigating with the keyboard arrow keys or clicking each picture for the next.

Although these are better than either of my other experiments with caffenol, I obviously have a long way to go before I get really good, fine grain high contrast images. Still, as long as each attempt gets better I suppose that is progress!

Advertisements

5 thoughts on “Fujica stx-1, Fomapan 200 and Caffenol C-M

Leave a Comment

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s